Level Library
The Federal Lands Highway Divisions use a standard MicroStation V8 level library, FLH_Combined. Place all MicroStation elements on the appropriate level. For viewing convenience the level listing is split into the following functional categories:
Drafting | Existing | Proposed | Cross Sections
Proposed Feature Levels
The proposed feature levels are grouped into the following sections:
| Level Name | Description | By Level | |||
|---|---|---|---|---|---|
| Color | Line Style | Weight | |||
| Bridge | |||||
| P_BRG_Abutment | Proposed Abutment | 0 | 0 (Solid) | 0 | |
| P_BRG_Boat_ Dock | Proposed Boat Dock | 0 | 0 (Solid) | 0 | |
| P_BRG_Deck | Proposed Deck | 0 | 0 (Solid) | 0 | |
| P_BRG_Footing | Proposed Footing | 0 | 0 (Solid) | 0 | |
| P_BRG_Girder | Proposed Girder | 0 | 0 (Solid) | 0 | |
| P_BRG_Pier | Proposed Pier | 0 | 0 (Solid) | 0 | |
| P_BRG_Rail | Proposed Rail | 0 | 0 (Solid) | 0 | |
| Erosion Control | |||||
| P_EC_Berm | Proposed Berm | 0 | Berm | 2 | |
| P_EC_Check_ Dams | Proposed Check Dam | 0 | 0 (Solid) | 2 | |
| P_EC_Fiber_ Log | Proposed Fiber Log | 0 | 0 (Solid) | 0 | |
| P_EC_Misc | Proposed Misc. Erosion Control | 0 | 0 (Solid) | 0 | |
| P_EC_Rockeries | Proposed Rockeries | 0 | 0 (Solid) | 0 | |
| P_EC_Sand_Bags | Proposed Sand Bags | 0 | 0 (Solid) | 0 | |
| P_EC_Silt_Fence | Proposed Silt Fence | 0 | Silt_Fence | 2 | |
| P_EC_Straw_ Bales | Proposed Straw Bales | 0 | 0 (Solid) | 0 | |
| P_EC_Temporary_ Culvert_ Pipe | Proposed Temporary Culvert Pipe | 1 | P_Culvert | 2 | |
| P_EC_Temporary_ Diversion_ Channel | Proposed Temporary Diversion Channel | 1 | 0 (Solid) | 2 | |
| P_EC_Wattle | Proposed Wattle | 0 | 0 (Solid) | 0 | |
| Environment | |||||
| P_ENV_Wetland_ Mitigation | Proposed Wetland Mitigation | 0 | 0 (Solid) | 0 | |
| Edge of Pavement | |||||
| P_EOP_Edge_ Travel_ Way | Proposed Edge of Traveled Way | 18 | 0 (Solid) | 0 | |
| P_EOP_Shoulder_ in_ DGN | Proposed Shoulder in DGN | 18 | 0 (Solid) | 0 | |
| P_EOP_Widened_ Existing_ Super | Proposed Widened Existing Super | 0 | 0 (Solid) | 0 | |
| P_EOP_Widened_ Shape | Proposed Widened Shape | 0 | 0 (Solid) | 0 | |
| P_EOP_Widening_ A-F | Proposed Widening A thru F | 4 | 0 (Solid) | 0 | |
| Geomorphology | |||||
| P_GEO_DTM_Triangles | Proposed Digital Terrain Model Triangles | 0 | 0 (Solid) | 0 | |
| P_GEO_Soil_ Borings | Proposed Soil Borings | 0 | 1 (Dotted) | 1 | |
| Geopak | |||||
| P_GPK_Pattern_ 01 | Proposed Cross Section Pattern Line 01 | 11 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 02 | Proposed Cross Section Pattern Line 02 | 12 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 03 | Proposed Cross Section Pattern Line 03 | 13 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 04 | Proposed Cross Section Pattern Line 04 | 14 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 05 | Proposed Cross Section Pattern Line 05 | 15 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 06 | Proposed Cross Section Pattern Line 06 | 16 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 07 | Proposed Cross Section Pattern Line 07 | 17 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 08 | Proposed Cross Section Pattern Line 08 | 18 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 09 | Proposed Cross Section Pattern Line 09 | 19 | 0 (Solid) | 1 | |
| P_GPK_Pattern_ 10 | Proposed Cross Section Pattern Line 10 | 20 | 0 (Solid) | 1 | |
| P_GPK_Profile_ Cell | Geopak Cell-Profile | 0 | 0 (Solid) | 1 | |
| Horizontal Alignment | |||||
| P_HAL_Bearings | Proposed Bearings | 3 | 0 (Solid) | 1 | |
| P_HAL_Centerline | Proposed Centerline | 3 | 0 (Solid) | 6 | |
| P_HAL_Control_ Point_ Stations | Proposed Control Point Station | 0 | 0 (Solid) | 0 | |
| P_HAL_Curve_ Information | Proposed Curve Information | 3 | 0 (Solid) | 1 | |
| P_HAL_Point | Proposed Point | 0 | 0 (Solid) | 0 | |
| P_HAL_Stations | Proposed Stations | 3 | 0 (Solid) | 3 | |
| P_HAL_Tick_ Marks | Proposed Tick Marks | 3 | 0 (Solid) | 1 | |
| Hydraulics | |||||
| P_HYD_Arch_ or_ Elliptical_ Pipe | Proposed Arch or Elliptical Pipe | 7 | 0 (Solid) | 4 | |
| P_HYD_Bank_ Stabilization | Proposed Bank Stablilzation | 0 | 0 (Solid) | 0 | |
| P_HYD_Bedding_ Material | Proposed Bedding Material | 0 | 0 (Solid) | 0 | |
| P_HYD_Buried_ Ditch_ Line | Proposed Buried Ditch Line | 0 | 0 (Solid) | 0 | |
| P_HYD_Culvert_ Liner | Proposed Culvert Liner | 0 | 0 (Solid) | 0 | |
| P_HYD_Data_ Profile | Proposed Data Profile | 0 | 0 (Solid) | 0 | |
| P_HYD_Ditch | Proposed Dicth | 0 | 0 (Solid) | 0 | |
| P_HYD_Ditch_ Center_ Line | Proposed Ditch Center Line | 2 | 0 (Solid) | 1 | |
| P_HYD_Ditch_ Paved | Proposed Ditch Paved | 15 | 0 (Solid) | 1 | |
| P_HYD_Drainage | Proposed Drainage | 1 | P_Storm_Drain | 3 | |
| P_HYD_Energy_ Dissipaters | Proposed Energy Dissipaters | 0 | 0 (Solid) | 0 | |
| P_HYD_GeoComposite_ Drain | Proposed GeoComposite Drain | 5 | 0 (Solid) | 1 | |
| P_HYD_Grade_ Control | Proposed Grade Control | 0 | 0 (Solid) | 0 | |
| P_HYD_Habitat_ Structures | Proposed Habitat Structures | 0 | 0 (Solid) | 0 | |
| P_HYD_Hydraulics | Proposed Hydraulics | 2 | 0 (Solid) | 1 | |
| P_HYD_Inlets | Proposed Inlets | 6 | 0 (Solid) | 1 | |
| P_HYD_Manhole | Proposed Manhole | 13 | 0 (Solid) | 1 | |
| P_HYD_Ordinary_ High_ Water | Proposed Ordinary High Water | 0 | 0 (Solid) | 0 | |
| P_HYD_Outlet_ Pipe | Proposed Outlet Pipe | 0 | 0 (Solid) | 0 | |
| P_HYD_Perforated_ Underdrains | Proposed Perforated Underdrains | 76 | 0 (Solid) | 2 | |
| P_HYD_Pipe_ Culvert | Proposed Pipe Culvert | 1 | P_Culvert | 1 | |
| P_HYD_Pipe_ End_ Section | Proposed Pipe End Section | 1 | 0 (Solid) | 1 | |
| P_HYD_Pipe_ Headwall | Proposed Pipe Headwall | 1 | 0 (Solid) | 1 | |
| P_HYD_Pipe_ Outlet | Proposed Pipe Outlet | 1 | 0 (Solid) | 1 | |
| P_HYD_Rock_ RipRap | Proposed Rock RipRap | 0 | 0 (Solid) | 0 | |
| P_HYD_Stream_ Restoration | Proposed Stream Restoration | 0 | 0 (Solid) | 0 | |
| P_HYD_Underdrains | Proposed Underdrains | 0 | P_Underdrain | 1 | |
| P_HYD_Waterway | Proposed Waterway | 11 | 0 (Solid) | 1 | |
| Landscape | |||||
| P_LA_Boulders | Proposed Boulder | 0 | 0 (Solid) | 0 | |
| P_LA_Landscaping-Planting_ etc | Proposed Landscaping Planting etc. | 2 | 1 (Dotted) | 1 | |
| Roadway | |||||
| P_RDW_Approach_ Road_ Match_ Line | Proposed Approach Road Match Line | 1 | 1 (Dotted) | 1 | |
| P_RDW_Approach_ Road_ Symbol | Proposed Approach Road Symbol | 0 | 0 (Solid) | 0 | |
| P_RDW_Clearing_ Limits | Proposed Clearing Limits | 0 | 0 (Solid) | 0 | |
| P_RDW_Curb_ Stone | Proposed Stone Curb | 3 | 0 (Solid) | 1 | |
| P_RDW_Curb_ Type_ 1-3 | Proposed Curb, Types 1 thru 3 | 1 | 1 (Dotted) | 1 | |
| P_RDW_Cut_Fill_ Slope_ Exceptions | Proposed Cut, Fill, Slope Exceptions | 0 | 0 (Solid) | 0 | |
| P_RDW_Detour_ Line | Proposed Minimum Detour Width Line | 100 | 3 (Long-dashed) | 1 | |
| P_RDW_Ditch_ Foreslope_ Height_ Override | Proposed Ditch Foreslope Height Override | 132 | 0 (Solid) | 1 | |
| P_RDW_Ditch_ Foreslope_ Override | Proposed Ditch Foreslope Override | 162 | 0 (Solid) | 1 | |
| P_RDW_Edge_ of_ Subexcavation | Proposed Edge of Subexcavation | 0 | 0 (Solid) | 0 | |
| P_RDW_Fencing | Proposed Fencing | 1 | P_Fence | 1 | |
| P_RDW_Flatbottom_ Ditch_ Override | Proposed Flatbottom Ditch Override | 136 | 0 (Solid) | 1 | |
| P_RDW_Gate | Proposed Gate | 0 | P_Gate | 1 | |
| P_RDW_Guardrail_ Systems | Proposed Guardrail Systems | 7 | P_Guardrail | 1 | |
| P_RDW_Medians | Proposed Median | 114 | 0 (Solid) | 1 | |
| P_RDW_Roadway_ Obliteration_ (211) | Proposed Roadway Obliteration (211) | 0 | 0 (Solid) | 1 | |
| P_RDW_Saw_Cut_ Pavement_ (203) | Proposed Saw or Cut Pavemant (203) | 2 | 0 (Solid) | 2 | |
| P_RDW_Shoulder_ Foreslope_ Override | Proposed Shoulder Foreslope Override | 233 | 0 (Solid) | 1 | |
| P_RDW_Signs | Proposed Signs | 0 | P_Two_Posted_ Sign | 1 | |
| P_RDW_Slope_ Stake_ Limits | Proposed Slope Stake Limits | 2 | 0 (Solid) | 3 | |
| P_RDW_Slope_ Stake_ Limits_ Text | Proposed Slope Stake Limits Text | 0 | 0 (Solid) | 0 | |
| P_RDW_Slope_ Stake_ Reference_ Point_ (New_ Anci) | Proposed Slope Stake Reference Point (New_Anci) | 0 | 0 (Solid) | 0 | |
| P_RDW_SubExcavation_ Depth_ Override | Proposed Subexcavation Depth Override | 242 | 0 (Solid) | 1 | |
| P_RDW_Super_ Shapes | Proposed Super Shapes | 0 | 0 (Solid) | 0 | |
| P_RDW_Switchback_ Match_ Line | Proposed Switchback Earthwork Match Line | 111 | 4 (Dot-dashed) | 1 | |
| P_RDW_Terminal_ Section_ Type | Proposed Terminal Section Type | 7 | 0 (Solid) | 1 | |
| P_RDW_Walkways | Proposed Walkways | 0 | 0 (Solid) | 1 | |
| P_RDW_Walls | Proposed Walls | 58 | P_Wall | 1 | |
| Right-of-Way | |||||
| P_RW_Construction_ Easement | Proposed Construction Easement | 79 | CFL_Temporary_ Easement | 4 | |
| P_RW_Dimensions | Proposed Dimensions | 1 | 0 (Solid) | 2 | |
| P_RW_Parcel_ Block | Proposed Parcel Block | 58 | 0 (Solid) | 1 | |
| P_RW_Permanent_ Easement | Proposed Permanent Easement | 63 | Permanent_Easement_ Inline | 4 | |
| P_RW_Right_ of_ Way | Proposed Right-of-Way | 79 | P_Right-of-Way_ Inline | 4 | |
| P_RW_Staked_ Centerline | Proposed Staked Centerline | 2 | 0 (Solid) | 2 | |
| P_RW_Staked_ Right-of-Way | Proposed Staked Right-of-Way | 0 | 0 (Solid) | 1 | |
| Survey Manager Database | |||||
| P_SMD_Chain | Proposed Chain | 2 | 0 (Solid) | 2 | |
| P_SMD_Curve | Proposed Curve | 3 | 0 (Solid) | 2 | |
| P_SMD_Line | Proposed Line | 4 | 0 (Solid) | 2 | |
| P_SMD_Point | Proposed Point | 5 | 0 (Solid) | 2 | |
| P_SMD_Spiral | Proposed Spiral | 7 | 0 (Solid) | 2 | |
| P_SMD_Staked_ Pline | Proposed Centerline - Staked Horizontal Alignment | 9 | 0 (Solid) | 2 | |
| Structures | |||||
| P_STR_Benches | Proposed Benches | 0 | 0 (Solid) | 0 | |
| P_STR_Bike_ Rack | Proposed Bike Rack | 0 | 0 (Solid) | 0 | |
| P_STR_Build_ and_ Structures | Proposed Build and Structures | 0 | 0 (Solid) | 0 | |
| P_STR_Cattle_ Guard | Proposed Cattle Guard | 190 | 0 (Solid) | 1 | |
| P_STR_Concrete_ Barrier | Proposed Concrete Barrier | 8 | P_Concrete_ Barrier | 1 | |
| P_STR_Concrete_ Barrier_ Terminal_ Section_ Cell | Proposed Concrete Barrier Terminal Section | 8 | 0 (Solid) | 1 | |
| P_STR_Concrete_ Pad | Proposed Concrete Pad | 0 | 0 (Solid) | 0 | |
| P_STR_Guardwall | Proposed Guardwall | 162 | 0 (Solid) | 1 | |
| P_STR_Kiosk | Proposed Kiosk | 0 | 0 (Solid) | 0 | |
| P_STR_Mail_ Box | Proposed Mail Box | 0 | 0 (Solid) | 0 | |
| P_STR_Mechanically_ Stabilized_ Earth_ Wall | Proposed Mechanically Stabilized Earth Wall | 0 | 0 (Solid) | 1 | |
| P_STR_Medians | Proposed Medians | 0 | 0 (Solid) | 0 | |
| P_STR_Pedestrian_ Railing | Proposed Pedestrian Railing | 0 | 0 (Solid) | 0 | |
| P_STR_Restroom_ Facility | Proposed Restroom Facility | 0 | 0 (Solid) | 0 | |
| P_STR_Sidewalks | Proposed Sidewalks | 0 | 0 (Solid) | 1 | |
| P_STR_Wheelstop | Proposed Wheelstop | 0 | 0 (Solid) | 0 | |
| Traffic Control | |||||
| P_TC_Construction_ Traffic_ Control | Proposed Construction Traffic Control | 0 | 1 (Dotted) | 2 | |
| P_TC_Delineators | Proposed Delineators | 0 | 0 (Solid) | 0 | |
| P_TC_Markings_ Permanent | Proposed Permanent Markings | 4 | 0 (Solid) | 2 | |
| P_TC_Markings_ Temporary | Proposed Temporary Markings | 4 | 1 (Dotted) | 1 | |
| P_TC_Object_ Markers | Proposed Object Markers | 0 | 0 (Solid) | 0 | |
| P_TC_Signs_ Permanent | Proposed Permanent Signs | 0 | 0 (Solid) | 0 | |
| P_TC_Signs_ Temporary | Proposed Temporary Signs | 0 | 0 (Solid) | 0 | |
| P_TC_Snow_Pole_ Holder | Proposed Snow Pole Holder | 0 | 0 (Solid) | 0 | |
| Utilities | |||||
| P_UT_Irrigation_ Ditch | Proposed Irrigation Ditch | 0 | P_Irrigation_ Ditch | 1 | |
| P_UT_Misc | Proposed Miscellaneous Utilities | 0 | 0 (Solid) | 0 | |
| P_UT_Overhead_ CATV | Proposed Overhead CATV | 0 | P_Overhead_ CATV | 1 | |
| P_UT_Overhead_ Fiber_ Optic | Proposed Overhead Fiber Optic | 0 | P_Overhead_ Fiber_ Optic | 1 | |
| P_UT_Overhead_ Power_ Line | Proposed Overhead Power Line | 0 | P_Overhead_ Power | 1 | |
| P_UT_Overhead_ Telephone_ Line | Proposed Overhead Telephone Line | 0 | P_Overhead_ Telephone | 1 | |
| P_UT_Underground_ CATV | Proposed Underground Cable TV | 0 | P_Underground_ CATV | 1 | |
| P_UT_Underground_ Fiber_ Optic | Proposed Underground Fiber Optic | 0 | P_Underground_ Fiber_ Optic | 1 | |
| P_UT_Underground_ Gas_ Line | Proposed Underground Gas Line | 0 | P_Underground_ Gas | 1 | |
| P_UT_Underground_ Irrigation | Proposed Underground Irrigation | 0 | P_Underground_ Irrigation | 1 | |
| P_UT_Underground_ Misc | Proposed Miscellaneous Underground Utilities | 0 | 0 (Solid) | 0 | |
| P_UT_Underground_ Oil | Proposed Underground Oil | 0 | P_Underground_ Oil | 1 | |
| P_UT_Underground_ Power_ Line | Proposed Underground Power Line | 0 | P_Underground_ Power | 1 | |
| P_UT_Underground_ Sanitary_ Sewer | Proposed Sewer Line | 0 | P_Sanitary_ Sewer | 1 | |
| P_UT_Underground_ Telephone_ Line | Proposed Underground Telephone Line | 0 | P_Underground_ Telephone | 1 | |
| P_UT_Underground_ Water | Proposed Underground Water | 0 | P_Water_Line | 1 | |
| Vertical Alignment | |||||
| P_VAL_AUX | Proposed Auxiliary | 0 | 0 (Solid) | 0 | |
| P_VAL_Exist | Proposed Existing Alignment | 0 | 0 (Solid) | 0 | |
| P_VAL_Proposed | Proposed Vertical Alignment | 0 | 0 (Solid) | 0 | |
| P_VAL_VPI | Proposed VPI | 0 | 0 (Solid) | 0 | |
| P_VAL_X_and_ Y_ Axis_ Labels | Proposed X and Y Axis Labels | 3 | 0 (Solid) | 0 | |
From X:\V8_Resource\X_30\Standards\Library_Files\FLH_Combined.dgnlib dated 3/24/2009