CFLHD Detail Drawings (ORD Version): FP-14

Detail drawings are used on a continuing basis within each division to clarify the work required in the plans. CFLHD Detail Drawings are arranged by FP section.

The drawings are available in MicroStation (DGN) and Acrobat (PDF) formats.

157 - Soil Erosion and Sediment Control Date
V8i MicroStation File Acrobat Icon C157-50 - Silt Fence 10-2021
V8i MicroStation File Acrobat Icon C157-51 - Temporary Inlet Protection 10-2021
V8i MicroStation File Acrobat Icon C157-53 - Check Dam 10-2021
V8i MicroStation File Acrobat Icon C157-54 - Check Dam with Rolled Erosion Control Product 10-2021
V8i MicroStation File Acrobat Icon C157-55 - Fiber Roll 10-2021
V8i MicroStation File Acrobat Icon C157-57 - Slope Drain 10-2021
Top
204 - Excavation and Embankment Date
V8i MicroStation File Acrobat Icon C204-50 - Embankment Benching and Furrow Ditch 10-2021
V8i MicroStation File PDF File C204-51 - Subexcavation 10-2021
Top
251 - Riprap Date
V8i MicroStation File Acrobat Icon C251-50 - Placed Riprap At Culverts 10-2021
V8i MicroStation File Acrobat Icon C251-51 - Placed Riprap Between Cut and Fill 10-2021
Top
257 - Contractor Designed Retaining Walls Date
V8i MicroStation File Acrobat Icon C257-50 - Contractor Designed Mechanically Stabilized Earth Wall 10-2021
Top
501 - Minor Concrete Pavement Date
V8i MicroStation File Acrobat Icon C501-50 - Minor Cement Concrete Pavement Joints 10-2021
Top
602 - Culverts and Drains Date
V8i MicroStation File Acrobat Icon C602-50 - 24" Run Down and Pipe Anchor Assembly 10-2021
V8i MicroStation File Acrobat Icon C602-51 - 24" Buried Run Down and Pipe Anchor Assembly 10-2021
Top
606 - Corrugated Metal Spillways Date
V8i MicroStation File Acrobat Icon C606-50 - CMP Spillway Assembly with Down Drain 10-2021
Top
617 - Guardrail Date
* * C617-10 – (Old) G4 W-Beam Guardrail, Wood Posts
* No longer used for new installations.
Contact Division Safety Engineer for more information.
10-2021
* * C617-11 – (Old) G4 W-Beam Guardrail, Steel Posts
* No longer used for new installations.
Contact Division Safety Engineer for more information.
10-2021
V8i MicroStation File Acrobat Icon C617-13 – MGS and G4 W-Beam Guardrail, Installation in Rock 10-2021
* * C617-17 – (Old) G4 W-Beam Guardrail, Back Slope Anchor Terminal Type G4-BAT
* No longer used for new installations.
Contact Division Safety Engineer for more information.
10-2021
V8i MicroStation File Acrobat Icon C617-18 – MGS W-Beam Guardrail, Back Slope Anchor Terminal Type MGS-BAT 10-2021
V8i MicroStation File Acrobat Icon C617-19 – MGS and G4 W-Beam Guardrail, Type Flared Terminal 10-2021
V8i MicroStation File Acrobat Icon C617-20 – MGS and G4 W-Beam Guardrail, Type Tangent Terminal 10-2021
V8i MicroStation File Acrobat Icon C617-21 - CRG W-Beam Guardrail, Wood Posts 10-2021
V8i MicroStation File Acrobat Icon C617-22 - G4 W-Beam Guardrail, Cable Releasing Terminal Type CRT, Wood Posts 10-2021
V8i MicroStation File Acrobat Icon C617-23 - G4 W-Beam Guardrail, CRT Anchorage Assembly Details 10-2021
V8i MicroStation File Acrobat Icon C617-31 - MGS W-Beam Guardrail, Wood Posts 10-2021
V8i MicroStation File Acrobat Icon C617-32 - MGS W-Beam Guardrail, Steel Posts 10-2021
V8i MicroStation File Acrobat Icon C617-37 - MGS W-Beam Guardrail Long-Span System 10-2021
V8i MicroStation File Acrobat Icon C617-38 - MGS W-Beam Guardrail Steel Posts Attached to Box Culvert 10-2021
V8i MicroStation File Acrobat Icon C617-39 – G4 to MGS W-Beam Guardrail Transition 10-2021
V8i MicroStation File Acrobat Icon C617-60 - Steel-backed Timber Guardrail Type A & Type B 10-2021
V8i MicroStation File Acrobat Icon C617-61 – Steel-backed Timber Guardrail Terminal Section Type SBT-FAT 10-2021
V8i MicroStation File Acrobat Icon C617-62 – Steel-backed Timber Guardrail Terminal Section Type SBT-BAT 10-2021
V8i MicroStation File Acrobat Icon C617-63 – Steel-backed Timber Guardrail Around Circular Curves 70' Radius and Below 10-2021
V8i MicroStation File Acrobat Icon C617-64 – Steel-backed Timber Guardrail TL-2 Connection to Stone Masonry Guardwall 10-2021
V8i MicroStation File Acrobat Icon C617-65 – Steel-backed Timber Guardrail TL-3 Connection to Stone Masonry Guardwall 10-2021
V8i MicroStation File Acrobat Icon C617-66 – Steel-backed Timber Guardrail Connection to Curved Back Structure 10-2021
V8i MicroStation File Acrobat Icon C617-69 – TL-2 End Terminal for Steel-backed Timber Guardrail 10-2021
V8i MicroStation File Acrobat Icon C617-80 – Steel-backed Log Rail 10-2021
V8i MicroStation File Acrobat Icon C617-81 – Steel-backed Log Rail Blockout 10-2021
V8i MicroStation File Acrobat Icon C617-82 – Steel-backed Log Rail Terminal Section, Type SBL-FAT 10-2021
Top
619 - Fences, Gate, Cattleguards, and Ballard Posts Date
V8i MicroStation File Acrobat Icon C619-50 - Wire Fences with Steel Posts (Type 3) 10-2021
V8i MicroStation File Acrobat Icon C619-51 - Wire Fences with Wood Posts 10-2021
V8i MicroStation File Acrobat Icon C619-52 - Cattleguard Gate and Widening 10-2021
Top
629 - Rolled Erosion Control Product and Cellular Confinement Systems Date
V8i MicroStation File Acrobat Icon C629-50 - Rolled Erosion Control Product on Slopes 10-2021
V8i MicroStation File Acrobat Icon C629-51 - Rolled Erosion Control Product in Channels 10-2021
Top
633 - Permanent Traffic Control Date
V8i MicroStation File Acrobat Icon C633-50 - Rumble Strip 10-2021
V8i MicroStation File Acrobat Icon C633-51 - Delineators 10-2021
Top
634 - Permanent Pavement Markings Date
V8i MicroStation File Acrobat Icon C634-50 - Centerline Striping and Top Lift Pavement Joint 10-2021
Top

Standard Drawings  |  Top